megacli通过盘符定位物理盘_MegaCli使用[通俗易懂]

2022-05-26 13:52:54 浏览数 (2)

0.前沿介绍

1. lsscsi -s 查看盘符对应关系

2. 查看物理槽位占用情况

3.查看适配器(控制器)个数

4.查看控制器序号,名称,序列号

5.查看所有逻辑层次磁盘详细信息

6.查看所有物理层次磁盘详细信息

7.查看raid信息(对应到target id,即逻辑磁盘):

8. 查看是raid还是JBOD

9.查看物理磁盘和逻辑磁盘对应关系

10.附录:查询物理和逻辑所有磁盘信息

0.前沿介绍

PD:物理的磁盘信息

LD:逻辑的磁盘信息

MegaCli64 参数对大小写不敏感

a:Adapter,适配器,适配器即为阵列卡控制器,以下以‘控制器’简称

-LdPdInfo:物理和逻辑的信息

MegaCli64不是所有的磁盘阵列卡都可以使用,如果不支持,需要使用其他的工具,如storcli/percli等

1. lsscsi -s 查看盘符对应关系:

通过lsscsi查看磁盘情况,这里显示的是逻辑层的,比如sda实际上是二块盘组成的raid1.

The first entry on each line is the scsi_host,channel,target_number,LUN

[[email protected] MegaCli]# lsscsi -s

[0:2:0:0] disk DELL PERC H730P Mini 4.26 /dev/sda 299GB

[0:2:1:0] disk DELL PERC H730P Mini 4.26 /dev/sdb 599GB

[0:2:2:0] disk DELL PERC H730P Mini 4.26 /dev/sdc 599GB

[0:2:3:0] disk DELL PERC H730P Mini 4.26 /dev/sdd 599GB

[0:2:4:0] disk DELL PERC H730P Mini 4.26 /dev/sde 599GB

[0:2:5:0] disk DELL PERC H730P Mini 4.26 /dev/sdf 599GB

[0:2:6:0] disk DELL PERC H730P Mini 4.26 /dev/sdg 599GB

[0:2:7:0] disk DELL PERC H730P Mini 4.26 /dev/sdh 599GB

[0:2:8:0] disk DELL PERC H730P Mini 4.26 /dev/sdi 599GB

[0:2:9:0] disk DELL PERC H730P Mini 4.26 /dev/sdj 599GB

[0:2:10:0] disk DELL PERC H730P Mini 4.26 /dev/sdk 599GB

[0:2:11:0] disk DELL PERC H730P Mini 4.26 /dev/sdl 599GB

[0:2:12:0] disk DELL PERC H730P Mini 4.26 /dev/sdm 479GB

[0:2:13:0] disk DELL PERC H730P Mini 4.26 /dev/sdn 479GB

[0:2:14:0] disk DELL PERC H730P Mini 4.26 /dev/sdo 479GB

[[email protected] MegaCli]#

2. 查看物理槽位占用情况:

[[email protected] MegaCli]# ./MegaCli64 -PDList -a0 | grep Slot

Slot Number: 0

Slot Number: 1

Slot Number: 2

Slot Number: 3

Slot Number: 4

Slot Number: 5

Slot Number: 6

Slot Number: 7

Slot Number: 8

Slot Number: 9

Slot Number: 10

Slot Number: 11

Slot Number: 12

Slot Number: 21

Slot Number: 22

Slot Number: 23

这里可以看到磁盘物理占用的槽位为16个,lsscsi显示共15条,是因为sda是raid1,占用2个槽位。

3.查看适配器(控制器)个数

适配器即为阵列卡控制器,以下以‘控制器’简称

[[email protected] MegaCli]# ./MegaCli64 -adpCount

Controller Count: 1.

Exit Code: 0x01

4.查看控制器序号,名称,序列号

[[email protected] MegaCli]# ./MegaCli64 -AdpAllInfo -Aall | grep -E "Adapter|Product Name|Serial"

Adapter #0

Product Name : PERC H730P Mini

Serial No : 64F01JN

Serial Debugger : Present

5.查看所有逻辑层次磁盘详细信息

语法:MegaCli -LDInfo -Lx|-L0,1,2|-Lall -aN|-a0,1,2|-aALL

这里LD即Target Id;

[[email protected] MegaCli]# ./MegaCli64 -LDInfo -L14 -a0

Adapter 0 -- Virtual Drive Information:

Virtual Drive: 14 (Target Id: 14)

Name :

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Size : 446.625 GB

Sector Size : 512

Is VD emulated : Yes

Parity Size : 0

State : Optimal

Strip Size : 64 KB

Number Of Drives : 1

Span Depth : 1

Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disk's Default

Encryption Type : None

Default Power Savings Policy: Controller Defined

Current Power Savings Policy: None

Can spin up in 1 minute: No

LD has drives that support T10 power conditions: No

LD's IO profile supports MAX power savings with cached writes: No

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

6.查看所有物理层次磁盘详细信息

语法:MegaCli64 -PDlist -aALL

[[email protected] MegaCli]# ./MegaCli64 -PDlist -aALl

Adapter #0

Enclosure Device ID: 32

Slot Number: 0

Drive's position: DiskGroup: 0, Span: 0, Arm: 0

Enclosure position: 1

Device Id: 0

WWN: 5000C50096E10F14

Sequence Number: 2

Media Error Count: 0

Other Error Count: 0

Predictive Failure Count: 0

Last Predictive Failure Event Seq Number: 0

PD Type: SAS

Raw Size: 279.396 GB [0x22ecb25c Sectors]

Non Coerced Size: 278.896 GB [0x22dcb25c Sectors]

Coerced Size: 278.875 GB [0x22dc0000 Sectors]

Sector Size: 512

Logical Sector Size: 512

Physical Sector Size: 512

Firmware state: Online, Spun Up

Device Firmware Level: VT31

Shield Counter: 0

Successful diagnostics completion on : N/A

SAS Address(0): 0x5000c50096e10f15

SAS Address(1): 0x0

Connected Port Number: 0(path0)

Inquiry Data: SEAGATE ST300MP0005 VT31S7K11KGK

FDE Capable: Not Capable

FDE Enable: Disable

Secured: Unsecured

Locked: Unlocked

Needs EKM Attention: No

Foreign State: None

Device Speed: 12.0Gb/s

Link Speed: 12.0Gb/s

Media Type: Hard Disk Device

Drive Temperature :34C (93.20 F)

PI Eligibility: Yes

Number of bytes of user data in LBA: 512

Drive is formatted for PI information: Yes

PI: PI with type 2

Port-0 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Port-1 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Drive has flagged a S.M.A.R.T alert : No

Enclosure Device ID: 32

Slot Number: 1

Drive's position: DiskGroup: 0, Span: 0, Arm: 1

Enclosure position: 1

Device Id: 1

WWN: 5000C50096E13580

Sequence Number: 2

Media Error Count: 0

Other Error Count: 0

Predictive Failure Count: 0

Last Predictive Failure Event Seq Number: 0

PD Type: SAS

Raw Size: 279.396 GB [0x22ecb25c Sectors]

Non Coerced Size: 278.896 GB [0x22dcb25c Sectors]

Coerced Size: 278.875 GB [0x22dc0000 Sectors]

Sector Size: 512

Logical Sector Size: 512

Physical Sector Size: 512

Firmware state: Online, Spun Up

Device Firmware Level: VT31

Shield Counter: 0

Successful diagnostics completion on : N/A

SAS Address(0): 0x5000c50096e13581

SAS Address(1): 0x0

Connected Port Number: 0(path0)

Inquiry Data: SEAGATE ST300MP0005 VT31S7K11K9J

FDE Capable: Not Capable

FDE Enable: Disable

Secured: Unsecured

Locked: Unlocked

Needs EKM Attention: No

Foreign State: None

Device Speed: 12.0Gb/s

Link Speed: 12.0Gb/s

Media Type: Hard Disk Device

Drive Temperature :32C (89.60 F)

PI Eligibility: Yes

Number of bytes of user data in LBA: 512

Drive is formatted for PI information: Yes

PI: PI with type 2

Port-0 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Port-1 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Drive has flagged a S.M.A.R.T alert : No

Enclosure Device ID: 32

Slot Number: 2

Drive's position: DiskGroup: 1, Span: 0, Arm: 0

Enclosure position: 1

Device Id: 2

WWN: 50000396B81B83B0

Sequence Number: 2

Media Error Count: 0

Other Error Count: 0

Predictive Failure Count: 0

Last Predictive Failure Event Seq Number: 0

PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]

Coerced Size: 558.375 GB [0x45cc0000 Sectors]

Sector Size: 512

Logical Sector Size: 512

Physical Sector Size: 512

Firmware state: Online, Spun Up

Device Firmware Level: DK04

Shield Counter: 0

Successful diagnostics completion on : N/A

SAS Address(0): 0x50000396b81b83b2

SAS Address(1): 0x0

Connected Port Number: 0(path0)

Inquiry Data: TOSHIBA AL13SXB60EN DK04Z5C0A04RFHRC

FDE Capable: Not Capable

FDE Enable: Disable

Secured: Unsecured

Locked: Unlocked

Needs EKM Attention: No

Foreign State: None

Device Speed: 12.0Gb/s

Link Speed: 12.0Gb/s

Media Type: Hard Disk Device

Drive Temperature :31C (87.80 F)

PI Eligibility: Yes

Number of bytes of user data in LBA: 512

Drive is formatted for PI information: Yes

PI: PI with type 2

Port-0 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Port-1 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Drive has flagged a S.M.A.R.T alert : No

...

...

7.查看raid信息(对应到target id,即逻辑磁盘):

//RAID Level对应关系

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0 RAID0

RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0 RAID1

RAID Level : Primary-5, Secondary-0, RAID Level Qualifier-3 RAID5

RAID Level : Primary-1, Secondary-3, RAID Level Qualifier-0 RAID10

//Raid卡磁盘缓存模式

[[email protected] MegaCli]# ./MegaCli64 -LDGetProp -Cache -LALL -aALL

Adapter 0-VD 0(target id: 0): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU

Adapter 0-VD 1(target id: 1): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU

Adapter 0-VD 2(target id: 2): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU

Adapter 0-VD 3(target id: 3): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU

Adapter 0-VD 4(target id: 4): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU

Adapter 0-VD 5(target id: 5): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU

Adapter 0-VD 6(target id: 6): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU

Adapter 0-VD 7(target id: 7): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU

Adapter 0-VD 8(target id: 8): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU

Adapter 0-VD 9(target id: 9): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU

Adapter 0-VD 10(target id: 10): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU

Adapter 0-VD 11(target id: 11): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU

Adapter 0-VD 12(target id: 12): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU

Adapter 0-VD 13(target id: 13): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU

Adapter 0-VD 14(target id: 14): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU

Exit Code: 0x00

//Raid卡磁盘raid模式

[[email protected] MegaCli]# ./MegaCli64 -ldinfo -LALL -aALL | grep -E "Target Id|RAID Level"

Virtual Drive: 0 (Target Id: 0)

RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0

Virtual Drive: 1 (Target Id: 1)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Virtual Drive: 2 (Target Id: 2)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Virtual Drive: 3 (Target Id: 3)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Virtual Drive: 4 (Target Id: 4)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Virtual Drive: 5 (Target Id: 5)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Virtual Drive: 6 (Target Id: 6)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Virtual Drive: 7 (Target Id: 7)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Virtual Drive: 8 (Target Id: 8)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Virtual Drive: 9 (Target Id: 9)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Virtual Drive: 10 (Target Id: 10)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Virtual Drive: 11 (Target Id: 11)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Virtual Drive: 12 (Target Id: 12)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Virtual Drive: 13 (Target Id: 13)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Virtual Drive: 14 (Target Id: 14)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

[[email protected] MegaCli]#

8. 查看是raid还是JBOD

//Firmware state : Online, Spun Up 代表是raid

//Firmware state : JBOD 代表是JBOD

[[email protected] MegaCli]# ./MegaCli64 -PDList -aAll | grep -E "Raw Size|Firmware state|Slot"

Slot Number: 0

Raw Size: 279.396 GB [0x22ecb25c Sectors]

Firmware state: Online, Spun Up

Slot Number: 1

Raw Size: 279.396 GB [0x22ecb25c Sectors]

Firmware state: Online, Spun Up

Slot Number: 2

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Firmware state: Online, Spun Up

Slot Number: 3

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Firmware state: Online, Spun Up

Slot Number: 4

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Firmware state: Online, Spun Up

Slot Number: 5

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Firmware state: Online, Spun Up

Slot Number: 6

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Firmware state: Online, Spun Up

Slot Number: 7

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Firmware state: Online, Spun Up

Slot Number: 8

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Firmware state: Online, Spun Up

Slot Number: 9

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Firmware state: Online, Spun Up

Slot Number: 10

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Firmware state: Online, Spun Up

Slot Number: 11

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Firmware state: Online, Spun Up

Slot Number: 12

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Firmware state: Online, Spun Up

Slot Number: 21

Raw Size: 447.130 GB [0x37e436b0 Sectors]

Firmware state: Online, Spun Up

Slot Number: 22

Raw Size: 447.130 GB [0x37e436b0 Sectors]

Firmware state: Online, Spun Up

Slot Number: 23

Raw Size: 447.130 GB [0x37e436b0 Sectors]

Firmware state: Online, Spun Up

[[email protected] MegaCli]#

9.查看物理磁盘和逻辑磁盘对应关系

语法:./MegaCli64 -LdPdInfo -aALL, 该命令是物理和逻辑查询的总和,信息相对比较全;

查看物理磁盘槽位。结合lsscsi 的target id进行判断。

这里‘Target Id’应该和lsscsi的[x:x:x:x] 第三个字段对应,这个应该可以确定,但没有证据支撑;另外如果节点有多个阵列卡,那么需要综合判断;

[[email protected] MegaCli]# ./MegaCli64 -LdPdInfo -a0 | grep -iE "slot|Virtual Drive|PD|Raw Size|RAID Level"

Virtual Drive: 0 (Target Id: 0)

RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0

Span: 0 - Number of PDs: 2 // 这里可以看到包括2块磁盘(RAID1)

PD: 0 Information //磁盘1

Slot Number: 0

PD Type: SAS

Raw Size: 279.396 GB [0x22ecb25c Sectors]

PD: 1 Information //磁盘2

Slot Number: 1

PD Type: SAS

Raw Size: 279.396 GB [0x22ecb25c Sectors]

Virtual Drive: 1 (Target Id: 1)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Span: 0 - Number of PDs: 1

PD: 0 Information

Slot Number: 2

PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Virtual Drive: 2 (Target Id: 2)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Span: 0 - Number of PDs: 1

PD: 0 Information

Slot Number: 3

PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Virtual Drive: 3 (Target Id: 3)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Span: 0 - Number of PDs: 1

PD: 0 Information

Slot Number: 4

PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Virtual Drive: 4 (Target Id: 4)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Span: 0 - Number of PDs: 1

PD: 0 Information

Slot Number: 5

PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Virtual Drive: 5 (Target Id: 5)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Span: 0 - Number of PDs: 1

PD: 0 Information

Slot Number: 6

PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Virtual Drive: 6 (Target Id: 6)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Span: 0 - Number of PDs: 1

PD: 0 Information

Slot Number: 7

PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Virtual Drive: 7 (Target Id: 7)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Span: 0 - Number of PDs: 1

PD: 0 Information

Slot Number: 8

PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Virtual Drive: 8 (Target Id: 8)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Span: 0 - Number of PDs: 1

PD: 0 Information

Slot Number: 9

PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Virtual Drive: 9 (Target Id: 9)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Span: 0 - Number of PDs: 1

PD: 0 Information

Slot Number: 10

PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Virtual Drive: 10 (Target Id: 10)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Span: 0 - Number of PDs: 1

PD: 0 Information

Slot Number: 11

PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Virtual Drive: 11 (Target Id: 11)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Span: 0 - Number of PDs: 1

PD: 0 Information

Slot Number: 12

PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Virtual Drive: 12 (Target Id: 12)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Span: 0 - Number of PDs: 1

PD: 0 Information

Slot Number: 21

PD Type: SATA

Raw Size: 447.130 GB [0x37e436b0 Sectors]

Virtual Drive: 13 (Target Id: 13)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Span: 0 - Number of PDs: 1

PD: 0 Information

Slot Number: 22

PD Type: SATA

Raw Size: 447.130 GB [0x37e436b0 Sectors]

Virtual Drive: 14 (Target Id: 14)

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Span: 0 - Number of PDs: 1

PD: 0 Information

Slot Number: 23

PD Type: SATA

Raw Size: 447.130 GB [0x37e436b0 Sectors]

[[email protected] MegaCli]#

10.附录:查询物理和逻辑所有磁盘信息

[[email protected] MegaCli]# ./MegaCli64 -LdPdInfo -a0 | grep -iE "slot|Virtual Drive|PD|Raw Size|RAID Level"

Adapter #0

Number of Virtual Disks: 15

Virtual Drive: 0 (Target Id: 0)

Name :

RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0

Size : 278.875 GB

Sector Size : 512

Is VD emulated : No

Mirror Data : 278.875 GB

State : Optimal

Strip Size : 64 KB

Number Of Drives : 2

Span Depth : 1

Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disk's Default

Encryption Type : None

Default Power Savings Policy: Controller Defined

Current Power Savings Policy: None

Can spin up in 1 minute: Yes

LD has drives that support T10 power conditions: Yes

LD's IO profile supports MAX power savings with cached writes: No

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

Number of Spans: 1

Span: 0 - Number of PDs: 2

PD: 0 Information

Enclosure Device ID: 32

Slot Number: 0

Drive's position: DiskGroup: 0, Span: 0, Arm: 0

Enclosure position: 1

Device Id: 0

WWN: 5000C50096E10F14

Sequence Number: 2

Media Error Count: 0

Other Error Count: 0

Predictive Failure Count: 0

Last Predictive Failure Event Seq Number: 0

PD Type: SAS

Raw Size: 279.396 GB [0x22ecb25c Sectors]

Non Coerced Size: 278.896 GB [0x22dcb25c Sectors]

Coerced Size: 278.875 GB [0x22dc0000 Sectors]

Sector Size: 512

Logical Sector Size: 512

Physical Sector Size: 512

Firmware state: Online, Spun Up

Device Firmware Level: VT31

Shield Counter: 0

Successful diagnostics completion on : N/A

SAS Address(0): 0x5000c50096e10f15

SAS Address(1): 0x0

Connected Port Number: 0(path0)

Inquiry Data: SEAGATE ST300MP0005 VT31S7K11KGK

FDE Capable: Not Capable

FDE Enable: Disable

Secured: Unsecured

Locked: Unlocked

Needs EKM Attention: No

Foreign State: None

Device Speed: 12.0Gb/s

Link Speed: 12.0Gb/s

Media Type: Hard Disk Device

Drive Temperature :34C (93.20 F)

PI Eligibility: Yes

Number of bytes of user data in LBA: 512

Drive is formatted for PI information: Yes

PI: PI with type 2

Port-0 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Port-1 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Drive has flagged a S.M.A.R.T alert : No

PD: 1 Information

Enclosure Device ID: 32

Slot Number: 1

Drive's position: DiskGroup: 0, Span: 0, Arm: 1

Enclosure position: 1

Device Id: 1

WWN: 5000C50096E13580

Sequence Number: 2

Media Error Count: 0

Other Error Count: 0

Predictive Failure Count: 0

Last Predictive Failure Event Seq Number: 0

PD Type: SAS

Raw Size: 279.396 GB [0x22ecb25c Sectors]

Non Coerced Size: 278.896 GB [0x22dcb25c Sectors]

Coerced Size: 278.875 GB [0x22dc0000 Sectors]

Sector Size: 512

Logical Sector Size: 512

Physical Sector Size: 512

Firmware state: Online, Spun Up

Device Firmware Level: VT31

Shield Counter: 0

Successful diagnostics completion on : N/A

SAS Address(0): 0x5000c50096e13581

SAS Address(1): 0x0

Connected Port Number: 0(path0)

Inquiry Data: SEAGATE ST300MP0005 VT31S7K11K9J

FDE Capable: Not Capable

FDE Enable: Disable

Secured: Unsecured

Locked: Unlocked

Needs EKM Attention: No

Foreign State: None

Device Speed: 12.0Gb/s

Link Speed: 12.0Gb/s

Media Type: Hard Disk Device

Drive Temperature :32C (89.60 F)

PI Eligibility: Yes

Number of bytes of user data in LBA: 512

Drive is formatted for PI information: Yes

PI: PI with type 2

Port-0 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Port-1 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 1 (Target Id: 1)

Name :

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Size : 558.375 GB

Sector Size : 512

Is VD emulated : No

Parity Size : 0

State : Optimal

Strip Size : 64 KB

Number Of Drives : 1

Span Depth : 1

Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disk's Default

Encryption Type : None

Default Power Savings Policy: Controller Defined

Current Power Savings Policy: None

Can spin up in 1 minute: Yes

LD has drives that support T10 power conditions: Yes

LD's IO profile supports MAX power savings with cached writes: No

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

Number of Spans: 1

Span: 0 - Number of PDs: 1

PD: 0 Information

Enclosure Device ID: 32

Slot Number: 2

Drive's position: DiskGroup: 1, Span: 0, Arm: 0

Enclosure position: 1

Device Id: 2

WWN: 50000396B81B83B0

Sequence Number: 2

Media Error Count: 0

Other Error Count: 0

Predictive Failure Count: 0

Last Predictive Failure Event Seq Number: 0

PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]

Coerced Size: 558.375 GB [0x45cc0000 Sectors]

Sector Size: 512

Logical Sector Size: 512

Physical Sector Size: 512

Firmware state: Online, Spun Up

Device Firmware Level: DK04

Shield Counter: 0

Successful diagnostics completion on : N/A

SAS Address(0): 0x50000396b81b83b2

SAS Address(1): 0x0

Connected Port Number: 0(path0)

Inquiry Data: TOSHIBA AL13SXB60EN DK04Z5C0A04RFHRC

FDE Capable: Not Capable

FDE Enable: Disable

Secured: Unsecured

Locked: Unlocked

Needs EKM Attention: No

Foreign State: None

Device Speed: 12.0Gb/s

Link Speed: 12.0Gb/s

Media Type: Hard Disk Device

Drive Temperature :30C (86.00 F)

PI Eligibility: Yes

Number of bytes of user data in LBA: 512

Drive is formatted for PI information: Yes

PI: PI with type 2

Port-0 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Port-1 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 2 (Target Id: 2)

Name :

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Size : 558.375 GB

Sector Size : 512

Is VD emulated : No

Parity Size : 0

State : Optimal

Strip Size : 64 KB

Number Of Drives : 1

Span Depth : 1

Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disk's Default

Encryption Type : None

Default Power Savings Policy: Controller Defined

Current Power Savings Policy: None

Can spin up in 1 minute: Yes

LD has drives that support T10 power conditions: Yes

LD's IO profile supports MAX power savings with cached writes: No

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

Number of Spans: 1

Span: 0 - Number of PDs: 1

PD: 0 Information

Enclosure Device ID: 32

Slot Number: 3

Drive's position: DiskGroup: 2, Span: 0, Arm: 0

Enclosure position: 1

Device Id: 3

WWN: 50000396B809270C

Sequence Number: 2

Media Error Count: 0

Other Error Count: 0

Predictive Failure Count: 0

Last Predictive Failure Event Seq Number: 0

PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]

Coerced Size: 558.375 GB [0x45cc0000 Sectors]

Sector Size: 512

Logical Sector Size: 512

Physical Sector Size: 512

Firmware state: Online, Spun Up

Device Firmware Level: DK04

Shield Counter: 0

Successful diagnostics completion on : N/A

SAS Address(0): 0x50000396b809270e

SAS Address(1): 0x0

Connected Port Number: 0(path0)

Inquiry Data: TOSHIBA AL13SXB60EN DK04Z550A0JTFHRC

FDE Capable: Not Capable

FDE Enable: Disable

Secured: Unsecured

Locked: Unlocked

Needs EKM Attention: No

Foreign State: None

Device Speed: 12.0Gb/s

Link Speed: 12.0Gb/s

Media Type: Hard Disk Device

Drive Temperature :30C (86.00 F)

PI Eligibility: Yes

Number of bytes of user data in LBA: 512

Drive is formatted for PI information: Yes

PI: PI with type 2

Port-0 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Port-1 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 3 (Target Id: 3)

Name :

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Size : 558.375 GB

Sector Size : 512

Is VD emulated : No

Parity Size : 0

State : Optimal

Strip Size : 64 KB

Number Of Drives : 1

Span Depth : 1

Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disk's Default

Encryption Type : None

Default Power Savings Policy: Controller Defined

Current Power Savings Policy: None

Can spin up in 1 minute: Yes

LD has drives that support T10 power conditions: Yes

LD's IO profile supports MAX power savings with cached writes: No

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

Number of Spans: 1

Span: 0 - Number of PDs: 1

PD: 0 Information

Enclosure Device ID: 32

Slot Number: 4

Drive's position: DiskGroup: 3, Span: 0, Arm: 0

Enclosure position: 1

Device Id: 4

WWN: 50000396B82387B8

Sequence Number: 2

Media Error Count: 0

Other Error Count: 0

Predictive Failure Count: 0

Last Predictive Failure Event Seq Number: 0

PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]

Coerced Size: 558.375 GB [0x45cc0000 Sectors]

Sector Size: 512

Logical Sector Size: 512

Physical Sector Size: 512

Firmware state: Online, Spun Up

Device Firmware Level: DK04

Shield Counter: 0

Successful diagnostics completion on : N/A

SAS Address(0): 0x50000396b82387ba

SAS Address(1): 0x0

Connected Port Number: 0(path0)

Inquiry Data: TOSHIBA AL13SXB60EN DK04Z5E0A0FMFHRC

FDE Capable: Not Capable

FDE Enable: Disable

Secured: Unsecured

Locked: Unlocked

Needs EKM Attention: No

Foreign State: None

Device Speed: 12.0Gb/s

Link Speed: 12.0Gb/s

Media Type: Hard Disk Device

Drive Temperature :30C (86.00 F)

PI Eligibility: Yes

Number of bytes of user data in LBA: 512

Drive is formatted for PI information: Yes

PI: PI with type 2

Port-0 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Port-1 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 4 (Target Id: 4)

Name :

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Size : 558.375 GB

Sector Size : 512

Is VD emulated : No

Parity Size : 0

State : Optimal

Strip Size : 64 KB

Number Of Drives : 1

Span Depth : 1

Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disk's Default

Encryption Type : None

Default Power Savings Policy: Controller Defined

Current Power Savings Policy: None

Can spin up in 1 minute: Yes

LD has drives that support T10 power conditions: Yes

LD's IO profile supports MAX power savings with cached writes: No

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

Number of Spans: 1

Span: 0 - Number of PDs: 1

PD: 0 Information

Enclosure Device ID: 32

Slot Number: 5

Drive's position: DiskGroup: 4, Span: 0, Arm: 0

Enclosure position: 1

Device Id: 5

WWN: 50000396A831F5DC

Sequence Number: 2

Media Error Count: 0

Other Error Count: 0

Predictive Failure Count: 0

Last Predictive Failure Event Seq Number: 0

PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]

Coerced Size: 558.375 GB [0x45cc0000 Sectors]

Sector Size: 512

Logical Sector Size: 512

Physical Sector Size: 512

Firmware state: Online, Spun Up

Device Firmware Level: DK04

Shield Counter: 0

Successful diagnostics completion on : N/A

SAS Address(0): 0x50000396a831f5de

SAS Address(1): 0x0

Connected Port Number: 0(path0)

Inquiry Data: TOSHIBA AL13SXB60EN DK04Y5X0A0JNFHRC

FDE Capable: Not Capable

FDE Enable: Disable

Secured: Unsecured

Locked: Unlocked

Needs EKM Attention: No

Foreign State: None

Device Speed: 12.0Gb/s

Link Speed: 12.0Gb/s

Media Type: Hard Disk Device

Drive Temperature :31C (87.80 F)

PI Eligibility: Yes

Number of bytes of user data in LBA: 512

Drive is formatted for PI information: Yes

PI: PI with type 2

Port-0 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Port-1 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 5 (Target Id: 5)

Name :

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Size : 558.375 GB

Sector Size : 512

Is VD emulated : No

Parity Size : 0

State : Optimal

Strip Size : 64 KB

Number Of Drives : 1

Span Depth : 1

Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disk's Default

Encryption Type : None

Default Power Savings Policy: Controller Defined

Current Power Savings Policy: None

Can spin up in 1 minute: Yes

LD has drives that support T10 power conditions: Yes

LD's IO profile supports MAX power savings with cached writes: No

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

Number of Spans: 1

Span: 0 - Number of PDs: 1

PD: 0 Information

Enclosure Device ID: 32

Slot Number: 6

Drive's position: DiskGroup: 5, Span: 0, Arm: 0

Enclosure position: 1

Device Id: 6

WWN: 50000396B81099DC

Sequence Number: 2

Media Error Count: 0

Other Error Count: 0

Predictive Failure Count: 0

Last Predictive Failure Event Seq Number: 0

PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]

Coerced Size: 558.375 GB [0x45cc0000 Sectors]

Sector Size: 512

Logical Sector Size: 512

Physical Sector Size: 512

Firmware state: Online, Spun Up

Device Firmware Level: DK04

Shield Counter: 0

Successful diagnostics completion on : N/A

SAS Address(0): 0x50000396b81099de

SAS Address(1): 0x0

Connected Port Number: 0(path0)

Inquiry Data: TOSHIBA AL13SXB60EN DK04Z570A0RAFHRC

FDE Capable: Not Capable

FDE Enable: Disable

Secured: Unsecured

Locked: Unlocked

Needs EKM Attention: No

Foreign State: None

Device Speed: 12.0Gb/s

Link Speed: 12.0Gb/s

Media Type: Hard Disk Device

Drive Temperature :31C (87.80 F)

PI Eligibility: Yes

Number of bytes of user data in LBA: 512

Drive is formatted for PI information: Yes

PI: PI with type 2

Port-0 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Port-1 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 6 (Target Id: 6)

Name :

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Size : 558.375 GB

Sector Size : 512

Is VD emulated : No

Parity Size : 0

State : Optimal

Strip Size : 64 KB

Number Of Drives : 1

Span Depth : 1

Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disk's Default

Encryption Type : None

Default Power Savings Policy: Controller Defined

Current Power Savings Policy: None

Can spin up in 1 minute: Yes

LD has drives that support T10 power conditions: Yes

LD's IO profile supports MAX power savings with cached writes: No

Bad Blocks Exist: Yes

PI type: No PI

Is VD Cached: No

Number of Spans: 1

Span: 0 - Number of PDs: 1

PD: 0 Information

Enclosure Device ID: 32

Slot Number: 7

Drive's position: DiskGroup: 6, Span: 0, Arm: 0

Enclosure position: 1

Device Id: 7

WWN: 50000396B8109BBC

Sequence Number: 2

Media Error Count: 1

Other Error Count: 0

Predictive Failure Count: 0

Last Predictive Failure Event Seq Number: 0

PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]

Coerced Size: 558.375 GB [0x45cc0000 Sectors]

Sector Size: 512

Logical Sector Size: 512

Physical Sector Size: 512

Firmware state: Online, Spun Up

Device Firmware Level: DK04

Shield Counter: 0

Successful diagnostics completion on : N/A

SAS Address(0): 0x50000396b8109bbe

SAS Address(1): 0x0

Connected Port Number: 0(path0)

Inquiry Data: TOSHIBA AL13SXB60EN DK04Z570A0STFHRC

FDE Capable: Not Capable

FDE Enable: Disable

Secured: Unsecured

Locked: Unlocked

Needs EKM Attention: No

Foreign State: None

Device Speed: 12.0Gb/s

Link Speed: 12.0Gb/s

Media Type: Hard Disk Device

Drive Temperature :34C (93.20 F)

PI Eligibility: Yes

Number of bytes of user data in LBA: 512

Drive is formatted for PI information: Yes

PI: PI with type 2

Port-0 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Port-1 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 7 (Target Id: 7)

Name :

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Size : 558.375 GB

Sector Size : 512

Is VD emulated : No

Parity Size : 0

State : Optimal

Strip Size : 64 KB

Number Of Drives : 1

Span Depth : 1

Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disk's Default

Encryption Type : None

Default Power Savings Policy: Controller Defined

Current Power Savings Policy: None

Can spin up in 1 minute: Yes

LD has drives that support T10 power conditions: Yes

LD's IO profile supports MAX power savings with cached writes: No

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

Number of Spans: 1

Span: 0 - Number of PDs: 1

PD: 0 Information

Enclosure Device ID: 32

Slot Number: 8

Drive's position: DiskGroup: 7, Span: 0, Arm: 0

Enclosure position: 1

Device Id: 8

WWN: 50000396B81B83D0

Sequence Number: 2

Media Error Count: 0

Other Error Count: 0

Predictive Failure Count: 0

Last Predictive Failure Event Seq Number: 0

PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]

Coerced Size: 558.375 GB [0x45cc0000 Sectors]

Sector Size: 512

Logical Sector Size: 512

Physical Sector Size: 512

Firmware state: Online, Spun Up

Device Firmware Level: DK04

Shield Counter: 0

Successful diagnostics completion on : N/A

SAS Address(0): 0x50000396b81b83d2

SAS Address(1): 0x0

Connected Port Number: 0(path0)

Inquiry Data: TOSHIBA AL13SXB60EN DK04Z5C0A04VFHRC

FDE Capable: Not Capable

FDE Enable: Disable

Secured: Unsecured

Locked: Unlocked

Needs EKM Attention: No

Foreign State: None

Device Speed: 12.0Gb/s

Link Speed: 12.0Gb/s

Media Type: Hard Disk Device

Drive Temperature :36C (96.80 F)

PI Eligibility: Yes

Number of bytes of user data in LBA: 512

Drive is formatted for PI information: Yes

PI: PI with type 2

Port-0 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Port-1 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 8 (Target Id: 8)

Name :

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Size : 558.375 GB

Sector Size : 512

Is VD emulated : No

Parity Size : 0

State : Optimal

Strip Size : 64 KB

Number Of Drives : 1

Span Depth : 1

Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disk's Default

Encryption Type : None

Default Power Savings Policy: Controller Defined

Current Power Savings Policy: None

Can spin up in 1 minute: Yes

LD has drives that support T10 power conditions: Yes

LD's IO profile supports MAX power savings with cached writes: No

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

Number of Spans: 1

Span: 0 - Number of PDs: 1

PD: 0 Information

Enclosure Device ID: 32

Slot Number: 9

Drive's position: DiskGroup: 8, Span: 0, Arm: 0

Enclosure position: 1

Device Id: 9

WWN: 50000396B81B83E4

Sequence Number: 2

Media Error Count: 0

Other Error Count: 0

Predictive Failure Count: 0

Last Predictive Failure Event Seq Number: 0

PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]

Coerced Size: 558.375 GB [0x45cc0000 Sectors]

Sector Size: 512

Logical Sector Size: 512

Physical Sector Size: 512

Firmware state: Online, Spun Up

Device Firmware Level: DK04

Shield Counter: 0

Successful diagnostics completion on : N/A

SAS Address(0): 0x50000396b81b83e6

SAS Address(1): 0x0

Connected Port Number: 0(path0)

Inquiry Data: TOSHIBA AL13SXB60EN DK04Z5C0A04XFHRC

FDE Capable: Not Capable

FDE Enable: Disable

Secured: Unsecured

Locked: Unlocked

Needs EKM Attention: No

Foreign State: None

Device Speed: 12.0Gb/s

Link Speed: 12.0Gb/s

Media Type: Hard Disk Device

Drive Temperature :32C (89.60 F)

PI Eligibility: Yes

Number of bytes of user data in LBA: 512

Drive is formatted for PI information: Yes

PI: PI with type 2

Port-0 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Port-1 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 9 (Target Id: 9)

Name :

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Size : 558.375 GB

Sector Size : 512

Is VD emulated : No

Parity Size : 0

State : Optimal

Strip Size : 64 KB

Number Of Drives : 1

Span Depth : 1

Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disk's Default

Encryption Type : None

Default Power Savings Policy: Controller Defined

Current Power Savings Policy: None

Can spin up in 1 minute: Yes

LD has drives that support T10 power conditions: Yes

LD's IO profile supports MAX power savings with cached writes: No

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

Number of Spans: 1

Span: 0 - Number of PDs: 1

PD: 0 Information

Enclosure Device ID: 32

Slot Number: 10

Drive's position: DiskGroup: 9, Span: 0, Arm: 0

Enclosure position: 1

Device Id: 10

WWN: 50000396B82386E8

Sequence Number: 2

Media Error Count: 0

Other Error Count: 0

Predictive Failure Count: 0

Last Predictive Failure Event Seq Number: 0

PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]

Coerced Size: 558.375 GB [0x45cc0000 Sectors]

Sector Size: 512

Logical Sector Size: 512

Physical Sector Size: 512

Firmware state: Online, Spun Up

Device Firmware Level: DK04

Shield Counter: 0

Successful diagnostics completion on : N/A

SAS Address(0): 0x50000396b82386ea

SAS Address(1): 0x0

Connected Port Number: 0(path0)

Inquiry Data: TOSHIBA AL13SXB60EN DK04Z5E0A0FFFHRC

FDE Capable: Not Capable

FDE Enable: Disable

Secured: Unsecured

Locked: Unlocked

Needs EKM Attention: No

Foreign State: None

Device Speed: 12.0Gb/s

Link Speed: 12.0Gb/s

Media Type: Hard Disk Device

Drive Temperature :31C (87.80 F)

PI Eligibility: Yes

Number of bytes of user data in LBA: 512

Drive is formatted for PI information: Yes

PI: PI with type 2

Port-0 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Port-1 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 10 (Target Id: 10)

Name :

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Size : 558.375 GB

Sector Size : 512

Is VD emulated : No

Parity Size : 0

State : Optimal

Strip Size : 64 KB

Number Of Drives : 1

Span Depth : 1

Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disk's Default

Encryption Type : None

Default Power Savings Policy: Controller Defined

Current Power Savings Policy: None

Can spin up in 1 minute: Yes

LD has drives that support T10 power conditions: Yes

LD's IO profile supports MAX power savings with cached writes: No

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

Number of Spans: 1

Span: 0 - Number of PDs: 1

PD: 0 Information

Enclosure Device ID: 32

Slot Number: 11

Drive's position: DiskGroup: 10, Span: 0, Arm: 0

Enclosure position: 1

Device Id: 11

WWN: 50000396B81B83E0

Sequence Number: 2

Media Error Count: 0

Other Error Count: 0

Predictive Failure Count: 0

Last Predictive Failure Event Seq Number: 0

PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]

Coerced Size: 558.375 GB [0x45cc0000 Sectors]

Sector Size: 512

Logical Sector Size: 512

Physical Sector Size: 512

Firmware state: Online, Spun Up

Device Firmware Level: DK04

Shield Counter: 0

Successful diagnostics completion on : N/A

SAS Address(0): 0x50000396b81b83e2

SAS Address(1): 0x0

Connected Port Number: 0(path0)

Inquiry Data: TOSHIBA AL13SXB60EN DK04Z5C0A04WFHRC

FDE Capable: Not Capable

FDE Enable: Disable

Secured: Unsecured

Locked: Unlocked

Needs EKM Attention: No

Foreign State: None

Device Speed: 12.0Gb/s

Link Speed: 12.0Gb/s

Media Type: Hard Disk Device

Drive Temperature :31C (87.80 F)

PI Eligibility: Yes

Number of bytes of user data in LBA: 512

Drive is formatted for PI information: Yes

PI: PI with type 2

Port-0 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Port-1 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 11 (Target Id: 11)

Name :

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Size : 558.375 GB

Sector Size : 512

Is VD emulated : No

Parity Size : 0

State : Optimal

Strip Size : 64 KB

Number Of Drives : 1

Span Depth : 1

Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disk's Default

Encryption Type : None

Default Power Savings Policy: Controller Defined

Current Power Savings Policy: None

Can spin up in 1 minute: Yes

LD has drives that support T10 power conditions: Yes

LD's IO profile supports MAX power savings with cached writes: No

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

Number of Spans: 1

Span: 0 - Number of PDs: 1

PD: 0 Information

Enclosure Device ID: 32

Slot Number: 12

Drive's position: DiskGroup: 11, Span: 0, Arm: 0

Enclosure position: 1

Device Id: 12

WWN: 50000396B8205F4C

Sequence Number: 2

Media Error Count: 0

Other Error Count: 0

Predictive Failure Count: 0

Last Predictive Failure Event Seq Number: 0

PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]

Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]

Coerced Size: 558.375 GB [0x45cc0000 Sectors]

Sector Size: 512

Logical Sector Size: 512

Physical Sector Size: 512

Firmware state: Online, Spun Up

Device Firmware Level: DK04

Shield Counter: 0

Successful diagnostics completion on : N/A

SAS Address(0): 0x50000396b8205f4e

SAS Address(1): 0x0

Connected Port Number: 0(path0)

Inquiry Data: TOSHIBA AL13SXB60EN DK04Z5C0A0E7FHRC

FDE Capable: Not Capable

FDE Enable: Disable

Secured: Unsecured

Locked: Unlocked

Needs EKM Attention: No

Foreign State: None

Device Speed: 12.0Gb/s

Link Speed: 12.0Gb/s

Media Type: Hard Disk Device

Drive Temperature :30C (86.00 F)

PI Eligibility: Yes

Number of bytes of user data in LBA: 512

Drive is formatted for PI information: Yes

PI: PI with type 2

Port-0 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Port-1 :

Port status: Active

Port's Linkspeed: 12.0Gb/s

Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 12 (Target Id: 12)

Name :

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Size : 446.625 GB

Sector Size : 512

Is VD emulated : Yes

Parity Size : 0

State : Optimal

Strip Size : 64 KB

Number Of Drives : 1

Span Depth : 1

Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disk's Default

Encryption Type : None

Default Power Savings Policy: Controller Defined

Current Power Savings Policy: None

Can spin up in 1 minute: No

LD has drives that support T10 power conditions: No

LD's IO profile supports MAX power savings with cached writes: No

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

Number of Spans: 1

Span: 0 - Number of PDs: 1

PD: 0 Information

Enclosure Device ID: 32

Slot Number: 21

Drive's position: DiskGroup: 12, Span: 0, Arm: 0

Enclosure position: 1

Device Id: 21

WWN: 55cd2e404c18ebe1

Sequence Number: 2

Media Error Count: 0

Other Error Count: 0

Predictive Failure Count: 0

Last Predictive Failure Event Seq Number: 0

PD Type: SATA

Raw Size: 447.130 GB [0x37e436b0 Sectors]

Non Coerced Size: 446.630 GB [0x37d436b0 Sectors]

Coerced Size: 446.625 GB [0x37d40000 Sectors]

Sector Size: 512

Logical Sector Size: 512

Physical Sector Size: 4096

Firmware state: Online, Spun Up

Device Firmware Level: 0140

Shield Counter: 0

Successful diagnostics completion on : N/A

SAS Address(0): 0x500056b3dd23cbd5

Connected Port Number: 0(path0)

Inquiry Data: BTHC6022021H480MGN INTEL SSDSC2BX480G4 G2010140

FDE Capable: Not Capable

FDE Enable: Disable

Secured: Unsecured

Locked: Unlocked

Needs EKM Attention: No

Foreign State: None

Device Speed: 6.0Gb/s

Link Speed: 6.0Gb/s

Media Type: Solid State Device

Drive: Not Certified

Drive Temperature :21C (69.80 F)

PI Eligibility: No

Drive is formatted for PI information: No

PI: No PI

Drive's NCQ setting : N/A

Port-0 :

Port status: Active

Port's Linkspeed: 6.0Gb/s

Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 13 (Target Id: 13)

Name :

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Size : 446.625 GB

Sector Size : 512

Is VD emulated : Yes

Parity Size : 0

State : Optimal

Strip Size : 64 KB

Number Of Drives : 1

Span Depth : 1

Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disk's Default

Encryption Type : None

Default Power Savings Policy: Controller Defined

Current Power Savings Policy: None

Can spin up in 1 minute: No

LD has drives that support T10 power conditions: No

LD's IO profile supports MAX power savings with cached writes: No

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

Number of Spans: 1

Span: 0 - Number of PDs: 1

PD: 0 Information

Enclosure Device ID: 32

Slot Number: 22

Drive's position: DiskGroup: 13, Span: 0, Arm: 0

Enclosure position: 1

Device Id: 22

WWN: 55cd2e404c1f3b86

Sequence Number: 2

Media Error Count: 0

Other Error Count: 0

Predictive Failure Count: 0

Last Predictive Failure Event Seq Number: 0

PD Type: SATA

Raw Size: 447.130 GB [0x37e436b0 Sectors]

Non Coerced Size: 446.630 GB [0x37d436b0 Sectors]

Coerced Size: 446.625 GB [0x37d40000 Sectors]

Sector Size: 512

Logical Sector Size: 512

Physical Sector Size: 4096

Firmware state: Online, Spun Up

Device Firmware Level: 0140

Shield Counter: 0

Successful diagnostics completion on : N/A

SAS Address(0): 0x500056b3dd23cbd6

Connected Port Number: 0(path0)

Inquiry Data: BTHC613401Z5480MGN INTEL SSDSC2BX480G4 G2010140

FDE Capable: Not Capable

FDE Enable: Disable

Secured: Unsecured

Locked: Unlocked

Needs EKM Attention: No

Foreign State: None

Device Speed: 6.0Gb/s

Link Speed: 6.0Gb/s

Media Type: Solid State Device

Drive: Not Certified

Drive Temperature :21C (69.80 F)

PI Eligibility: No

Drive is formatted for PI information: No

PI: No PI

Drive's NCQ setting : N/A

Port-0 :

Port status: Active

Port's Linkspeed: 6.0Gb/s

Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 14 (Target Id: 14)

Name :

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Size : 446.625 GB

Sector Size : 512

Is VD emulated : Yes

Parity Size : 0

State : Optimal

Strip Size : 64 KB

Number Of Drives : 1

Span Depth : 1

Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disk's Default

Encryption Type : None

Default Power Savings Policy: Controller Defined

Current Power Savings Policy: None

Can spin up in 1 minute: No

LD has drives that support T10 power conditions: No

LD's IO profile supports MAX power savings with cached writes: No

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

Number of Spans: 1

Span: 0 - Number of PDs: 1

PD: 0 Information

Enclosure Device ID: 32

Slot Number: 23

Drive's position: DiskGroup: 14, Span: 0, Arm: 0

Enclosure position: 1

Device Id: 23

WWN: 55cd2e404c18ec02

Sequence Number: 2

Media Error Count: 0

Other Error Count: 0

Predictive Failure Count: 0

Last Predictive Failure Event Seq Number: 0

PD Type: SATA

Raw Size: 447.130 GB [0x37e436b0 Sectors]

Non Coerced Size: 446.630 GB [0x37d436b0 Sectors]

Coerced Size: 446.625 GB [0x37d40000 Sectors]

Sector Size: 512

Logical Sector Size: 512

Physical Sector Size: 4096

Firmware state: Online, Spun Up

Device Firmware Level: 0140

Shield Counter: 0

Successful diagnostics completion on : N/A

SAS Address(0): 0x500056b3dd23cbd7

Connected Port Number: 0(path0)

Inquiry Data: BTHC6022022G480MGN INTEL SSDSC2BX480G4 G2010140

FDE Capable: Not Capable

FDE Enable: Disable

Secured: Unsecured

Locked: Unlocked

Needs EKM Attention: No

Foreign State: None

Device Speed: 6.0Gb/s

Link Speed: 6.0Gb/s

Media Type: Solid State Device

Drive: Not Certified

Drive Temperature :21C (69.80 F)

PI Eligibility: No

Drive is formatted for PI information: No

PI: No PI

Drive's NCQ setting : N/A

Port-0 :

Port status: Active

Port's Linkspeed: 6.0Gb/s

Drive has flagged a S.M.A.R.T alert : No

Exit Code: 0x00

0 人点赞